HL7 LLP (TCP/IP) Listener

HL7 LLP Listener – Monitors a specified TCP socket for HL7 messages.

Select the Static Polling Listener from the Listener Type drop-down. There are 3 tabs: Basic, Advanced and Mode.

Listener HL7 LLP Configuration

1. Basic – at the Basic tab you can specify:

Port: Specifies the TCP port listener, modified by the application server.
Synchronous: Specifies if a Synchronous Response transport will be used to provide ACK responses.
Timeout: Specifies how long the listener should wait for messages, which are interrupted before timing out the connection.

Listener or Adapter HL7 LLP Configuration

2. Advanced – at the Advanced tab you can specify:

Initialize on trigger only: If enabled, the listener doesn’t start up until a trigger initializes it.
Allow command-line invocation: If enabled, the listener can be invoked using the CLI client application.
Restart on listening error: If enabled, the listener will be restarted after an error occurs.
Ignore Inbound Ack: Ignore the Ack response.

Listener or Adapter Configuration Advanced Options

3. Mode – at the Mode tab, you can specify acknowledgment conditions. You can choose: Always, Error/Reject Only or Success Only.

Listener or Adapter Configuration ACK Mode Options