TCP/IP

HL7 LLP (TCP/IP) Listener

HL7 LLP Listener – Monitors a specified TCP socket for HL7 messages.

Select the Static Polling Listener from the Listener Type drop down. There are 3 tabs: Basic, Advanced and Mode.

ListenerHL7LLP1

1. Basic – at Basic tab you can specify:

Port: Specifies the TCP port listen at; modified by application server.
Synchronous: Specifies if a Synchronous Response transport will be used to provide ACK responses.
Timeout: Specifies how long the listener should wait for messages, which are interrupted before timing out the connection.

ListenerHL7LLP2

2. Advanced – at Advanced tab you can specify:

Initialize on trigger only: If enabled, listener doesn’t start up until a trigger initializes it.
Allow command-line invocation: If enabled, listener can be invoked using the CLI client application.
Restart on listening error: If enabled, listener will be restarted after error accur.
Ignore Inbound Ack: Ignore the Ack response.

ListenerHL7LLP3

3. Mode – at Mode tab, you can specify acknowledgement conditions. It can be Never, Always, Error/Reject Only, Success Only.

ListenerHL7LLP4

TAKE A TOUR

LISTENER NEXT STAGE >> GENERIC SOCKET LISTENER

NEXT STAGE >> B2B ADAPTERS – PROCESSORS